Monday, January 19, 2015

orchid flower types

Fault list
5.1 AC450: Controller load ................................................................................................. 5-1
5.2 ADA: 132 kV Switchyard .............................................................................................. 5-2
5.3 ADA10: 330kV Switchyard ........................................................................................... 5-3
5.4 BAA: Medium voltage system ....................................................................................... 5-5
5.5 BAA: Medium-voltage system ...................................................................................... 5-6
5.6 BAC: Generator circuit breaker .................................................................................... 5-8
5.7 BAT: Generator transformers, including cooling systems ............................................ 5-8
5.8 BAT10: Station service transformer ............................................................................ 5-17
5.9 BBT: Medium-voltage auxiliary power transformers ................................................... 5-17
5.10 BBT10: Medium-voltage auxiliary board incomerpower transformers ........................ 5-21
5.11 BBT10: Unit Auxiliary Transformer ............................................................................. 5-23
5.12 BBT20: Station service transformer ............................................................................ 5-23
5.13 BHR: Air conditioning ................................................................................................. 5-27
5.14 BJA: Low-voltage sub-distribution boards and transformers ...................................... 5-28
5.15 BJA02: LV Board ........................................................................................................ 5-32
5.16 BJA10: LV Board ........................................................................................................ 5-34
5.17 BPA: ........................................................................................................................... 5-35
5.18 BPA: SFC Sequencer ................................................................................................. 5-35
5.19 BPA: SSD ................................................................................................................... 5-36
5.20 BPA: Starting device ................................................................................................. 5-37
5.21 BPA10: SSD start cond .............................................................................................. 5-41
5.22 BRA: Low-voltage (UPS) distribution boards .............................................................. 5-41
5.23 BRB: Low-voltage (UPS) distribution boards .............................................................. 5-44
5.24 BRU: Converter (static), inverter. ............................................................................... 5-46
5.25 BTA: Battery system 1 ................................................................................................ 5-48
5.26 BTB: Battery system 2 ................................................................................................ 5-49
5.27 BTL: Battery charger 1 ............................................................................................... 5-50
5.28 BTM: Battery chargers 2 ............................................................................................. 5-52
5.29 BUA: DC Distribution board ........................................................................................ 5-54
5.30 BUB: DC Distribution board ........................................................................................ 5-56
5.31 BUB: DC Distribution board ....................................................................................... 5-58
5.32 BUC: DC Distribution board ........................................................................................ 5-60
5.33 BUC: DC Distribution board ....................................................................................... 5-62
5.34 BUC20: DC Distribution board .................................................................................... 5-64
5.35 CEC: Operation data counter ..................................................................................... 5-64
5.36 CJP: Fuel valve .......................................................................................................... 5-65
5.37 CJP: GT sequencer .................................................................................................... 5-65
5.38 CJP: Instrumentation and control cabinets for GT and EGATROL hardware ............ 5-67
5.39 CJP00: GT sequencer ................................................................................................ 5-68
5.40 CRC: Instrumentation and control equipment for GT and EGATROL ....................... 5-77